What the Study Found
- Smartphone voice clips alone sorted adults with and without type 2 diabetes at 0.724 balanced accuracy in men and 0.713 in women (chance is 0.5).
- Standard voice-analysis features alone scored lower than the transformer: 0.641 balanced accuracy in men and 0.628 in women.
- People with diabetes averaged about 15 years older than controls; strict age matching cut balanced accuracy to 0.597 in men and 0.561 in women.
- All 461 adults were recruited at four clinical sites in India and read English prompts; no outside dataset was available to test the model.
For two weeks, up to six times a day, adults in India opened an app on their own phones and read aloud whatever random sentence it served them. A transformer model trained on 14,759 smartphone voice recordings from 461 adults told people with type 2 diabetes apart from people without it with a balanced accuracy of about 72 percent in men and about 71 percent in women (guessing scores 50). That is the headline number, anyway. The details are messier.
Balanced accuracy averages two things: how often the model catches people who have diabetes, and how often it correctly clears people who do not, so a lopsided guesser cannot flatter itself. The same Klick Labs group reported higher raw accuracy in 2023 (89 percent in women, 86 percent in men), but the company itself says those figures should not be compared with the new ones, because the yardsticks, inputs and validation differ.
Reading Random Sentences Into a Phone
Earlier voice work leaned on hand-picked measurements such as jitter (tiny wobbles in pitch) and shimmer (tiny wobbles in loudness). This one converts each clip into a spectrogram, a picture of which frequencies are loud at which moment, and hands that image to an Audio Spectrogram Transformer first taught on a big library of everyday sounds, not speech. Because the model reads the whole picture, it can pick up combinations across frequency and time that nobody thought to list in advance. Men and women were modeled separately, and the data were split by person, so none of one person’s recordings could sit on both sides of the training line (a quiet way for voice models to cheat).
Does the picture add anything over the old-style measurements? It did. A baseline built on standard voice-analysis features reached a balanced accuracy of 0.641 in men and 0.628 in women, against 0.724 and 0.713 for the transformer. Independent work lands in similar territory: a Luxembourg-led team using a different voice model on 607 US adults reported broadly similar discrimination, with area under the curve scores (0.5 is a coin flip, 1 is perfect) of 0.75 in men and 0.71 in women.
The team set its threshold to favor catching cases over avoiding false alarms, and the trade-off shows in the women’s results: 0.783 of women with diabetes were flagged, but only 0.660 of those without it were cleared. In practice that would mean extra blood tests for a good many people who turn out to be fine. Fair enough, perhaps, for a screening idea.
The Age Gap Behind the Accuracy
“Now, we can literally see many more clues related to diabetes within vocal biomarkers,” says Yan Fossat at Klick Applied Sciences, the company behind the work and principal investigator of the study. He says the spectrogram approach found combinations of acoustic patterns that “werenโt on anyoneโs radar”.
One thing that was on everybody’s radar is age, and it is the awkward part. Men with type 2 diabetes averaged 50.29 years against 34.13 for the controls; for women it was 48.00 against 34.33, a gap of roughly 15 years in each. Voices change with age, and so does diabetes risk, so a model could be listening to birthdays rather than blood sugar. The authors tested that by matching ages strictly: with 69 men in each group, balanced accuracy fell to 0.597, and with 41 women in each group it fell to 0.561. Those matched groups were small, which costs a model training power on its own, yet the paper reads the drop as consistent with age contributing to the full-cohort signal.
Matching still left a residual gap of about a year, and body mass index, higher in the women with diabetes, remains an open confounder, the authors say, and body composition can muddy consumer gadgets too, as when fitness-watch calorie errors grew with body fat in one lab test.
Then there is who was recorded. Everyone came from four clinical sites in India, spoke English, read from a prompt and had no chronic condition other than diabetes, and no outside dataset was available to check the model against (a transformer that read old sleep studies did get a second-cohort check), so the authors expect that performance on other languages, phones and populations could be lower.
A Triage Idea, Not a Test
Klick’s release leads with the 72 and 71 percent figures and does not mention the age-matched rerun, the single-country sample or the missing outside check. The paper, accepted at the Journal of Biomedical and Health Informatics (published by the Institute of Electrical and Electronics Engineers (IEEE)) though not yet in its final edited form, is franker: it calls the work a technical validation rather than a clinical one and says the system should not be used to rule out diabetes or to stand in for guideline-based screening. If it survives prospective testing, the authors see it as a triage signal that nudges someone toward a standard blood sugar test. Whether a phone can ever do that job probably depends on whether the pattern holds up in people who are older, younger, differently accented and recording on other handsets.
For now, the sentence a phone hears is a long way from a diagnosis. Fossat says the group will keep exploring the associations between vocal biomarkers and type 2 diabetes, and a series of studies with Mayo Clinic in Florida, announced in June 2026, is where some of that work is headed.
Reference
Guermazi, B., Logerais, A., Huynh, E. Y., Oreskovic, J., Callanan, A., & Fossat, Y. (2026). V2D: Detection of type 2 diabetes using only smartphone voice recordings via spectro-temporal transformer embeddings. IEEE Journal of Biomedical and Health Informatics, 1โ17. https://doi.org/10.1109/jbhi.2026.3730729
- Study type: Cross-sectional machine-learning classification study (a technical validation); peer-reviewed, accepted in IEEE Journal of Biomedical and Health Informatics as an author’s version not yet fully edited.
- Sample size: 461 adults (157 women, 304 men), contributing 14,759 voice recordings after balancing.
- Model: Audio Spectrogram Transformer embeddings (pretrained on AudioSet) feeding sex-stratified classifiers, scored by fivefold nested cross-validation split by person.
- Inputs and assumptions: Mel-spectrograms of smartphone recordings of random English sentences; age, body mass index and blood pressure excluded from model inputs; people with prediabetes excluded.
- Duration: Two weeks of recording per participant, up to six clips a day, collected August 2021 to June 2022.
- Funding / conflicts of interest: Not reported in the manuscript (Acknowledgment section empty); the release comes from Klick Applied Sciences, where the principal investigator is a senior vice president.
- Data availability: Raw audio not shared for privacy; de-identified acoustic features and code may be shared on reasonable request.
- Preregistration: Data-collection protocol registered (CTRI/2021/08/035957); preregistration of this analysis not reported.
- Main limitation: Single dataset from four sites in India, English read speech, no external validation; age and body mass index confounding unresolved (age matching cut balanced accuracy to 0.597 in men, 0.561 in women).
FAQ
Why does age matter so much in a voice study of diabetes?
Age matters in a voice study of diabetes because voices change with age and so does diabetes risk, and the people with diabetes here averaged about 15 years older than the controls. When the researchers matched ages strictly, balanced accuracy fell to 0.597 in men and 0.561 in women, although the matched groups were small. The paper reads that drop as consistent with age contributing to the signal.
Could a phone replace a blood test for diabetes?
A phone could not replace a blood test for diabetes on this evidence. The paper says the system should not be used to rule out diabetes or to stand in for guideline-based screening, and it calls the work a technical rather than a clinical validation. If later tested prospectively, the authors see it as a triage signal that prompts a standard blood sugar test.
Is 72 percent balanced accuracy good enough for a screening tool?
A balanced accuracy of about 72 percent is well above the 50 a coin-flip guesser would score, but it is far from a settled screening test. In the women’s results the model flagged 0.783 of those with diabetes while clearing only 0.660 of those without it, so false alarms would be common. The study did not evaluate clinical usefulness or cost.
Will this work for people who do not speak English or live outside India?
Nobody knows yet whether this approach will work for people who do not speak English or live outside India. All recordings came from four clinical sites in India, with English read speech on personal phones, and no outside dataset was available to test the model. The authors say performance on other languages, devices and populations may be lower.